fuentes RSS
No RSS feed added
"Point-and-shoot" technology to instantly measure relative chlorophyll content Detects stress earlier than visual monitoring Technology based on an exclusive patent license from NASA Laser guides outline the edges of the measured sample area Calculates and displays a running average for multiple readings Connects to any GPS...
CM1000 NDVI FieldScout Portable Chlorophyll Meter. Part No. 2953.Normalized Difference Vegetation Index (NDVI).
◆ The WATER-PAM is the PAM fluorometer of choice when very low chlorophyll contents of samples require outstandingly sensitive fluorescence detection. The three different types of the WATER-PAM are designed to analyze suspension samples, surfaces, or a continuous water flow, respectively. ◆ The parameters measures are chlorophyll content and...
Chlorophyll Fluorescence System WALZMOBILE Version is dedicated to chlorophyll fluorescence imaging in the field. The MAXI and MINI versions may be combined with the Gas-Exchange System GFS-3000 thus integrating detailed spatial information on photosynthesis and with exact analysis of photosynthetic carbon fixation.
The DUAL-KLAS-NIR represents a significant advancement over the well-established DUAL-PAM-100 system. The DUAL-PAM-100 employs one pair of wavelengths in the near infrared (NIR) to measure absorption changes related to redox alterations of the photosystem I reaction center. Using four wavelength pairs in the NIR, the DUAL-KLAS-NIR is capable of...
High-performance Field and Laboratory Chlorophyll Fluorometer.Major Points of the PAM-2500: Saturation pulse as well as polyphasic rise analysis with time resolution down to 10 μs Latest generation light-emitting diodes for all internal light sources High sensitivity enabling high quality measurements with dilute suspensions of algae and cyanobacteria.
The chlorophyll fluorometer MONITORING-PAM is designed for unattended, long-term and multi-site monitoring of chlorophyll fluorescence in air or underwater. At each measuring site, compact and robust emitter-detector units measure modulated chlorophyll fluorescence and perform saturation pulse analysis.
JUNIOR-PAM and JUNIOR-PAM/W - Compact Fluorometer from WALZ The two versions of the JUNIOR-PAM fluorometer provide visible light of different spectral composition: the BLUE version emits between 400 and 500 nm with a maximum around 445 nm. The WHITE version shows a narrow-band blue emission peaking around 445 nm plus a broad band emission ranging from 475...
Gas-Exchange Cuvette in combining with DUAL-PAM-100 from WALZ
Outstanding Properties of the MICROSCOPY-PAM◆ Fluorescence detection by a highly sensitive red-enhanced photomultiplier tube◆ Single cell analysis◆ Version with blue or red light available
Chl Fluorescence & P700 AbsorbanceWALZ P700 Tutorial - Basic Concepts:
A MICRO-PAM system involves several light-weight chlorophyll fluorometers for field use. Being capable of multi-site monitoring of photosynthesis over weeks and months, the MICRO-PAM is tailored to study plant responses to environmental changes in nature and under controlled conditions. Due to its compact measuring heads, the MICRO-PAM is suited for...
WALZ Phytoplankton AnalyzerCompact Version and Modular VersionThe PHYTO-PAM-II instruments have universal reference files. We invite you to upload / download reference files PHYTO-PAM-II. The content and quality of the references have not been validated by Heinz Walz GmbH.Dr. Ulrich Schreiber has monitored the specific absorbance changes of ferredoxin...
Double-Modulation Fluorometer FL 6000 measures chlorophyll α (Chlα) fluorescence.Measured fluorescence emission is excited by a set of light-emitting diodes that generate measuring flashes of few microseconds in duration and low light intensity; the photochemistry is driven by single-turnover flashes or by continuous actinic irradiance.Chlorophyll α...
LaiPen LP-110 can work in two operation modes: Single sensor mode - reference measurement is taken before, after or during measurement with the same instrument; Two sensor mode - second instrument is used for automatic logging of reference signal.
Handy FluorCam FC 1000-H is a lightweight, portable device designed to obtain time-resolved chlorophyll fluorescence imaging of leaves, small plants, leaf segments, mosses, lichens, seeds, roots, plaque tissue, or algal colonies in both the field as in the laboratory.
Handy GFPCam FC 1000-H / GFP is a modified version of the popular Handy FluorCam. Its unique construction allows both time-resolved chlorophyll fluorescence imaging and GFP imaging. Handy GFPCam is a lightweight, portable system designed to image leaves, small plants, leaf segments, mosses, lichens, seeds, roots, plate tissue, or algal colonies both in...
The closed FluorCam FC 800-C is a popular and best-selling system for imaging the kinetics of chlorophyll fluorescence that can be extended to a multispectral version allowing the detection of various fluorescent signals. The standard version consists of a CCD camera and four fixed LED panels. LED panels provide uniform irradiance on samples up to 90 ×...
Custom FluorCams are complex multispectral imaging systems that are manufactured to very specific customer needs. They achieve all the capabilities and characteristics of standard FluorCams. Additionally, other imaging and scoring units can be incorporated into the system, such as an RGB camera for true color analysis or thermal imaging for sheet surface...