SF-L Ecomatik Sap Flow Sensor: 4 needles

Ecomatik

New

Improved Granier Sap Flow Sensor with four needles and a much higher accuracy. For trees diameter >15 cm.

It requires use of the CCS to feed the current.

580,00 €

Add to wishlist

The Sensor measures: Sap Flow
Cable Length: 5 meters
Power Supply: 12 V
Sensor for use in: Outdoor

The SF-L (SF-10) SAP Flow Sensor is an improved Granier sensor.
The improvements are:
Correction of measurement errors due to vertical temperature gradient of tree trunk: the vertical trunk temperature is measured separately and subtracted from the data of sap flow. In this way the sap flow is measured more accurately, and the zero-point of sap flow remains stable for a long time.
Continuous determination of water-saturation level of the tree body with a Dendrometer
New definition of zero sap flow: sap flow = 0 when the relative humidity in the crown => 100%, and the tree body is saturated with water (indicated by the dendrometer curve)  

Advantages:
Significant higher accuracy
Correct identification of zero sap flow
Correct Measurement of sap flow in night time
Additional data on tree growth measured by a dendrometer
Reusable sensor 

Disadvantages:
Not suitable for trees with diameters <15 cm 

Available Models
■ SF-G 20/33, depth of installation 20-33 mm
■ SF-G 20/43, depth of installation 20-43 mm
■ SF-G 20/63, depth of installation 20-63 mm

Delivery of Standard Version:

Sensor with 5 cable, weatherproof cap, Aluminium tubes

Options / Ordering Information
Cable extension (please specify in meters, but max. 20 m)
CCS power supply (one CCS is enough for up to 3 SF-L sensors). Requires constant current source (CCS) for 3 sap flow sensors (SF-L or SF-G or mixed).
Installation tools
Data Logger 

Compatible wih Data Loggers:
UX120-006M
 for up to 4 channels .

Name Sap Flow Sensor Type SF-L (SF 10)
Needle size Diameterr 1.5 mm, Length 33, 43, 63 mm
Cable length 5 m, extendable to 20 m
Suitable for tree size Diameter> 15 cm
Power supply CCS supplies up to 3 sensors and consumes 1 W (12 V x 84 mA DC, stabilized)
Output 0 µV to 1000 µV DC

 

 Options / Ordering Information:
■ Cable extension (please specify in meters, but max. 20 m)

■ CCS Constant Current Power Supply (one CCS is enough for up to 3 SF-G sensors)
■ Installation tools
■ Data Logger

SF-10: SF-L 20/33, depth of installation 20-33 mm
SF-11: SF-L 20/43, depth of installation 20-43 mm
SF-12: SF-L 20/63, depth of installation 20-63 mm

And available in cable lengths of: 5m, 10m, 15m and 20 meters.