PT-100
New
DISCONTINUED
The PlanTherm PT100 device allows quick and easy estimation of the thermal stability of plants, algae or cyanobacteria. A segment of algae leaf or cells is immersed in a water bath with deionized water and gradually heated from 20 ° C to 85 ° C, duration approx. 30 minutes. Linear heating is combined with continuous monitoring of changes in bath conductivity.
This product is no longer in stock
Availability date:
The measured conductivity-temperature curve makes it possible to determine the exact threshold temperature when ion leakage occurs from cells. The threshold temperature is taken as a measure of the thermal stability of the plants. Simultaneous detection of the intensity of chlorophyll a fl uorescence (the so-called minimum fl uorescence level - F0) during heating provides information on the thermal stability of primary photosynthetic processes in plant material. The PlanTherm device is designed for the analysis of various plant materials ranging from small to medium sized leaves or leaf segments.
PlanTherm PT 100 comes with a built-in Mini-PC with pre-installed Windows 10 operating system, offering a smart and intuitive user interface. The ProfleCon graphical user interface allows you to configure experiments, analyze data, and export measured curves to a textual output file. Graphs of the running experiment, measured raw data and analyzed results can be displayed on the main screen.
Applications
Rapid estimation of both constitutive and inducible heat tolerance of plants
Thermal stability of plants
Acclimatization responses and stress tolerance
Photosynthetic research
Biotic and abiotic stress detection
Resistance or susceptibility of the plant to stress factors.
Agriculture and horticulture
Software
Pre-installed Windows 10 operating system
ProfleCon control and visualization software
R software environment to run custom analysis on measured signals
Measured fluorescence parameters:
F0, fluorescence / temperature curve with estimation of up to 4 critical fluorescence points
Measured conductivity parameters:
Conductivity / temperature curve with estimation of critical points of conductivity
Fluorescence module excitation light sources:
460 nm for the saturation light and the FT measurement pulse; individual intensity settings
Protocols:
Custom defined linear heating (1-3 ° C / min) in a defined temperature range
Temperature control range:
20 - 85 ° C
Water bath volume:
7 ml
Conductivity measurement resolution:
0.01 µS
Temperature measurement resolution:
0.01 ° C
Shaker frequency:
0 - 2,000 RPM
Data sampling rate:
2 Hz
Typical samples:
Detached leaf segments of maximum size 0.5 × 2 cm
Analysis:
Predefined R script to search for critical points; free analysis scripts for custom modifications
Mini PC Configuration:
Intel NUC Golden Lake D33217GKE i3-3217-U 1.8 GHz; Minimum 90 GB SSD HD, 2 GB DDR3 RAM
Dimensions:
5 × 20 × 20 cm
Total weight:
2 kilograms
Power input:
Max. 70 W
Electric:
90 - 240 V
Replacement cuvette for PlanTherm PT 100
402.000-OG 10 mm pail
Sample holder for PlanTherm PT 100
Includes sample holder and sample holder bucket
Conductivity probe for PlanTherm PT 100
PlanTherm sensor
Magnetic stir bar for PlanTherm PT 100
3x8mm PTFE Magnetic Stirring Bar
960,00 €