Nvis 63T 5 1/2 and 6 1/2 Digital BenchTop Multimeters (Full scale Reading: 1.99,999)

Nvis63T

NVIS TECHNOLOGIES

New

The Nvis 62T, 5 digit and Nvis 63T, 6 digit are high speed, high accuracy, Digital Bench Top Multimeters that meet the measurement needs of voltage-current and resistor accurate measurements. Their outstanding performances, such as fast reading rates (Max. 45 Readings/Second) and DC voltage measurement accuracy up to 0.005% provide a high standard in your work bench.

Add to wishlist

  • Features:

- 12 different measurement capabilities
- DCV/ACV, DCI/ACI, W2 W/W4 W, Frequency/ period Diode Test /continuity- dB/dBm etc.
- High brightness vaccum fluorescent dual display
- True-rms AC voltage and current measurement, Frequency bandwidth up to 100 KHz/300 KHz
- DCV measurement accuracy up to 0.01 % / 0.005, resolution; 1 mV/0.1JL/V
- Max. measurement rate: 45 results per second
- Equal accuracy frequency measurement greater than 1 MHz, Min resolution 10 mHz
- Zeroing (REL) mode
- 2 W, 4 W Resistance measurement
- Build in mX+b, %, dB, dBm etc. mathematics calculation function
- 512 reading storage and MAX/ MIN/ AVER/ STD statistics
- HI/ IN/ LO for speed sieving
- RS-232 interface for easy communication and optional GPIB
- Calibration without opening the case
- 10 sets of meter status can be stored and loaded

Technical Specifications

Test Parameter

(DCV), (ACV), (DOI), (ACI), (ACI), (W 2 W), (W 4 W). (FREQ), (PERI), (CONT), (DIODE).

Mathematics Calculation Function

mX + b, % dB, dBm, REL

Range

Auto, Manual

Display

VFD

Trigger

Mode

INT/ MAN/ EXT

Programmable Time Delay

0 -6000mS

Reading Storage and Statistics

2 to 1024 sets of reading can be stored, loaded and counted Type of statistics : MAX. MIN. AVER. STD

Reading Hold

To give best stable reading for each of the Test Parameter according to the given accuracy

Limitation Measurement

To judge III. IN, LO and display with ALARM for 1 HI/LO

Storage setting

10 setting files can be stored loaded

Calibration

Recommended Fluke 5520A with NB 62 Accurate calibration software (option)

Communication Interface

GPIB (option), RS 232C. SCPI command programmable

Specifications

Accuracy : ± (reading % + full scale reading %)

Full Scale Reading and reading Rate (Reading /Second)

Reading Rate

Slow

Medium

Fast

Nvis 62T

Nvis 63T

Full scale Reading

119.999

1.99,999

119,999

11,999

Reading rate (reading /Sec.)

DCV, DCI

3.7

2.3

24

45

ACV, ACI

2.3

1.5

4.5

24

W- 2W

3.7

2.3

21

36

(DCV)

Range

Min. Resolution

Max. Accuracy (One year)

Nvis 62T

100mV-1000V

1mV

0.010% + 0.0035%

Nvis 63T

100mV-1000V

0.1mV

0.005% + 0.0010%

(DCI)

Range

Resolution

Max. Accuracy (One year)

Nvis 62T

10mA-10A

0.1μA

0.050% + 0.010%

Nvis 63T

10mA-10A

10nA

0.005% + 0.005%

(1kHz) (ACV)

Bandwidth

Range

Min. Resolution

Max. Accuracy (One year)

Nvis 62T

10Hz-100kHz

100mV-750V

1μV

0.10% + 0.10%

Nvis 63T

5Hz-300kHz

100mV-750V

0.1μV

0.06% + 0.05%

(ACI)

Bandwidth

Range

Min. Resolution

Max. Accuracy (One year)

Nvis 62T

10Hz-10kHz

10mA-10A

0.1μA

0.25% + 0.0.8%

Nvis 63T

10Hz-10kHz

10mA-10A

10nA

0.15% + 0.06%

(2W 4W)

Range

Measurement Current

Min. Resolution

Max. Accuracy Resolution(One year)

Nvis 62T

100-100M

0.7mA-1mA

1mΩ

0.030% + 0.005%

Nvis 63T

100-100M

0.7mA-1mA

100mΩ0.015% + 0.002%

(Frequency)

Range

Voltage Sensitivity

Min. Resolution

Max. Accuracy (One year)

Nvis 62T

5Hz 1.1MHz

40mVrms

10mHz

0.005% + 0.002%

30 other products in the same category: