5302-AQM Air Quality Monitor (0.3 μm to 25 μm) with TVOC Sensor

5302-AQM

Particles Plus

New

Measures the concentration of mass in μg / m³ and the indication of PM (Particle Matter)
Measure up to 6 simultaneous data channels.
Measure CO2, temperature and relative humidity with user alarm set points
Measures TVOC in parts per billion (Model 5302-AQM)
User adjustable one and two point sensor calibration compensation
User-selectable channel sizes
Long-lasting laser diode technology.
0.1 CFM (2.83 LPM) internal vacuum pump

Add to wishlist

Type of Instrument Particles in Air Monitor
The instrument measures: Optical Particle Counting
Instrument for: Particle Size
Function: Analyze Particle Size

The Particles Plus 5302-AQM Air Quality Monitor measures particles from 0.3 μm to 25.0 μm and has a mass concentration mode that approximates density in
μg/m³. The unit displays simultaneous PM1, PM2.5, PM5, PM10 and TPM data, while monitoring CO2, TVOC, Temperature, Humidity and Barometric Pressure. With an internal 0.1 CFM (2.83 LPM) vacuum pump, the 5302-AQM can be used as a stand-alone instrument or be easily integrated into a building management system via Ethernet or (optional) Wireless 802.11 b/g.
Particles Plus counters can be controlled and monitored remotely via web browser. The 5302-AQM’s mass concentration mode allows for density correction and refractivity index input for up to 6 particle size channels.

The Particles Plus® 5301-AQM and 5302-AQM Remote Air Quality Monitor measures and displays particle mass concentrations for PM1, PM2.5, PM5 and PM10 including temperature, relative humidity, CO2 (and TVOC in the 5302-AQM). This wall- mounted instrument is the most versatile remote air quality monitor available for fixed installations. The advanced power management and the industry’s first sleep mode, allows for long intervals between samples over extended and unattended operations. The AQM Series can easily integrate into a building automation and facility monitoring system via Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232. 

The 5301-AQM and 5302-AQM reports and displays 6 user-selectable particle size channels, as well as Carbon Dioxide (CO2), temperature, and relative humidity. The instrument monitors PM1, PM 2.5, PM5, PM 10 (and any other PM size value the user specifies) with an easy-to-use Channel Management control panel. The instrument also monitors flow, sensor status, date of last calibration, serial number, laser on-time, and date of manufacture for easy maintenance and warranty management. The remote monitor operates using a long-life internal 0.1 CFM pump. 

View data and generate environmental reports real-time on screen, via printer or USB key, through the versatile output options, or export to Particles Plus® Instrument Management Software during monitoring system or network failure. Particles Plus® instruments can be controlled and monitored remotely via web browser from any PC, tablet or smartphone supporting up to 20 concurrent user sessions. 

The 5301-AQM and 5302-AQM particle counter stores 45,000 time-stamped particle count and environmental data records for redundant protection in the event of a monitoring system or network failure. The AQM Series mass concentration mode approximates density in μg/m³ and PM (particle matter) allowing for density and refractive index corrections to ensure accuracy. All Particles Plus® counters meet ISO 21501-4 and JIS B9921. These instruments ensure compliance with an on-board pulse height analyzer.

Size Range 0.3 to 25 μm
Size Channels Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Flow rates 0.1 CFM (2.83 LPM)
Concentration Limit 4,000,000 Particles/ft³ @ 5% coincidence loss
Counting Efficiency 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Light Source Long Life Laser Diode
Zero Count <1 count / 5 minutes (<2 particles / ft³) (per ISO 21501-4 & JIS)
Count Modes Automatic, manual, real-time meter, cumulative/differential, count or concentration
Count Alarms 1 to 9,999,999 counts
Calibration NIST traceable
Display 4.3″ (10.9 cm) WQVGA (480×272) color touch screen
Vacuum Requirements External vacuum >15” (38.1 cm) of Hg
Number of Channels 6
Custom Size Channels Calibration for custom size channels available
Airflow Internally monitored
Audible Alarm Adjustable built-in alarm
Communication Modes Ethernet and USB
Optional Communication Modes Wireless 802.11 b/g, RS485 or RS232
Environmental Sensor Optional temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% relative humidity
Alarm Alarms on counts for all particle sizes, sensor failure, environmental sensors and flow
Standards ISO 21501-4 and JIS B9921
Calibration Recommended minimum once per year
External Surface Stainless steel
Dimensions (L x W x H) 5.2” x 2.3” x 8.9” (13.3 cm x 5.8 cm x 22.6 cm) includes barb fittings
Weight 2.6 lb (1.18 kg)
Accessories Quick start guide, operating manual on USB flash drive, isokinetic probe, power supply & cable
Optional Accessories Printed manual, temperature relative humidity sensor, isokinetic probes, purge filter, data cable, mounting bracket and sample tubing
Buffer Memory 45,000 sample records (rotating buffer) including particle count data and environmental data
Sample Time 1 second to 99 hours
Power 110 to 240 VAC 50/60 Hz universal in-line power supply
Operating Conditions 41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing
Storage Conditions 32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing
Warranty 2 Years. Extended warranties available.

30 other products in the same category: