- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
English
EUR €
RTR-322 log-EZ Wireless Kit Temperature and Humidity Data Logger
The user-friendly log-EZ can be easily used to measure and record temperature and humidity in various places such as homes and office buildings. It is possible to manage data recorded by multiple log-EZ units, that are placed in distant rooms, via one computer. Also, wireless communication makes data transmission easy and simple with no need for cables or gathering the log-EZ units to collect data.
Application Examples

* Monitoring and controlling temperature and humidity for heating and air conditioning
* Monitoring and controlling temperature and humidity in a private wine cellar
* Monitoring and controlling temperature and humidity in a private wine cellar
| FCC model / CE model |
"log-EZ" RTR-322
| ||
|---|---|---|---|
| Number of Channels | 2 Ch (Temperature/Humidity) | ||
| Measurement Items | Temperature | Humidity | |
| Measurement Range | 0 to 50°C | 15 to 90%RH | |
| Display Resolution | 0.1°C | 1% | |
| Accuracy | ±0.5°C [0 to 50°C] | ±5%RH [at 25°C 50%RH] | |
| LCD Refresh Interval | 4 sec. | ||
| Recording Interval | 10 min.(Fixed) | ||
| Logging Capacity | 1,440 data sets (One data set consists of readings for all channels in that type of unit.) (*1) | ||
| Operation Mode | Registration Mode |
After inserting battery: 5 min. (For First Remote Unit Registration) / 2 min. (For Battery Replacement) | |
| Recording Mode |
Overwrite the oldest data when capacity is full | ||
| LCD Displayed Items | Measurement and Recording Status / Amount of Recorded Data / Communication Status / Recording Mode / Battery Life Warning / Measurements (Temperature and Humidity: alternating display) / Unit of Measurement | ||
| Power | AA Alkaline Battery x 1 | ||
| Battery Life | About 6 months (*2) | ||
| Communication Method | Wireless Communication (internal antenna) between "log-EZ" (RTR-322) and "Wireless Dongle" (RTR-300) | ||
| Radio Standard Specifications | FCC Part15 Section247/ IC RSS-210 (Frequency Range: 2.4GHz(*3)) ETSI EN 300440-2 (Frequency Range: 2.4GHz(*3)) |
||
| Wireless Communication Range | About 50meters[160ft] (if unobstructed and direct) | ||
| Dimensions | Tubular Shape Dia 36mm x L85mm | ||
| Weight | About 62g (including AA Alkaline Battery) | ||
| Operationg Environment (*4) |
Temperature: 0 to 50°C Humidity: 90%RH or less (without condensation) |
||
| *1: Logging Capacity is the amount of data which can be stored in the unit; when the capacity is full, the oldest data is overwritten and recording continues. In order to store data continually, a PC is needed to receive data. *2: Battery life varies depending upon measuring environment, frequency of communication, and battery performance. (Example: If used at an interval of 1 min. to collect current readings, battery life expectancy is about 1.5 months.) *3: This Unit is not for use with a wireless LAN. *4: In environments where the temperature exceeds or falls below this range, there may be occasions when the recorded data is lost. |
|||
| FCC model / CE model |
Wireless Dongle RTR-300
|
|---|---|
| Power | USB Bus Power (5V) |
| Interface | USB |
| Radio Standard Specifications |
FCC Part15 Section247 / IC RSS-210 (Frequency Range: 2.4GHz (*1)) ETSI EN 300440-2 (Frequency Range: 2.4GHz (*1)) |
| Wireless Communication Range |
About 50 meters [160 ft] (if unobstructed and direct) |
| Dimensions | L79.5mm x W19.5mm x D9.4mm |
| Weight | 11g |
| Operationg Environment (*2) |
Temperature: 0 to 50°C Humidity: 90%RH or less (without condensation) |
| *1: This Unit is not for use with a wireless LAN. *2: In environments where the temperature exceeds or falls below this range, there may be occasions when the recorded data is lost. |
|
Dimensions
"log-EZ" RTR-322

1: LCD Display
2: Battery Cover
2: Battery Cover
Wireless Dongle RTR-300

RTR-322/300 KIT: Humid. & Temp. Logger + Wireless Dongle
RTR-322: Humid. & Temp. Logger<