129610A LHe/LN2
New
This product is no longer in stock
Availability date:
This cryostat system, a customized version of the Janis Research Company's model STVP cryostat is a versatile research tool, designed to operate between 5 K and 600 K. The sample itself is located in an inert, dry, static exchange gas, (e.g. helium), which ensures that the sample is not affected by exposure to cryogen vapor.
Liquid nitrogen (LN2) or liquid helium (LHe) can be used as the cryogen depending on the required operating temperature range. This allows standard tests to be performed using relatively low cost LN2 as the cryogen. Higher cost LHe can be substituted for the duration of tests where very low temperature is required, providing an economical solution to your test requirements.
Applications include:
Solartron Analytical, specialists in the design of precision impedance test equipment, has joined forces with cryogenic experts Janis Research Company Inc., to produce an advanced cryogenic materials characterization test system
The flexible solution for materials characterization...
The Janis Research Company special model STVP cryostat is a versatile research tool, designed to operate between 5 K and 600 K. The sample itself is located in an inert, dry, static exchange gas, (e.g. helium), which ensures that the sample is not affected by exposure to cryogen vapor.
Liquid nitrogen (LN2) or liquid helium (LHe) can be used as the cryogen depending on the required operating temperature range. This allows standard tests to be performed using relatively low cost LN2 as the cryogen. Higher cost LHe can be substituted for the duration of tests where very low temperature is required, providing an economical solution to your test requirements.
Applications include:
High performance..
The 129610A is a high performance temperature control system that provides comprehensive test facilities:
The unique flexibility of being able to switch between LN2 and LHe ensures that this high performance cryostat system will fit your requirements, now and in the future.
Solartron materials test systems...
The 129610A cryostat may be used together with any Solartron materials test system to run I-V, Pulse, C-V, Impedance, Mott-Schottky and a wide range of other materials test techniques, fully integrated with temperature control.
Cryostat (Special Model) | Janis STVP-200 special model with static gas sample chamber | |
Cryostat construction | Tubular cryostat with vacuum stroud and radiation shield | |
Sample Space | Static gas (e.g. helium) | |
Temperature range | 5 K to 600 K - LHe 78 K to 600 K - LN2 |
|
Temperature stability | ±0.05 K | |
Temperature probes | Type E thermocouple - Exchange gas heater |
|
Cryogen transfer line | LHe / LN2 transfer line (included) | |
Dimensions | 31' (786 mm) height, 5.75' (146 mm) diameter | |
Approximate Weight | 25 lb (11.3 kg) | |
Optional Dewars | - A dewar (LN2 or LHe) is needed to operate this system - Compatibility with LN2 dewars that are not supplied as part of the system cannot be guaranteed. |
|
Option A1 | LN2 dewar (10 L) LN-10 | |
Dimensions | 23' (584 mm) height, 11.25' (286 mm) diameter | |
Empty Weight | 12.5 lb (5.7 kg) | |
Option A2 | LN2 dewar (20 L) LN-20 | |
Dimensions | 24.6' (625 mm) height, 15' (381 mm) diameter | |
Empty Weight | 23 lb (10.4 kg) | |
Option A3 | LN2 dewar (50 L) LN-10 | |
Dimensions | 30.5' (775 mm) height, 18.5' (470 mm) diameter | |
Empty Weight | 38 lb (17.2) kg) | |
Option B1 (on application) | LHe dewars are usually provided by cryogen supplier with standard 0.5' transfer line fitting | |
Option C | Turbo pump (42L/s) TP-75 - or equivalent is needed for system operation. |
|
Temperature Controller (included) | ||
Controller | Lake Shore 332S-T2 Dual Loop (sample and heater) |
|
Dimensions | 8.5' (216 mm) W x 3.5' (89 mm) H x 14.5' (368 mm) D | |
Weight | 10.5 lb (4.8 kg) | |
Power V AC | 100, 120, 220, 240 (+6%, -10%), 50 or 60 Hz 150 VA | |
Interface | PC requires NI IEEE-488 interface - not included in system price | |
Solid Sample Holder (included) | ||
Electrodes | Gold-plated brass electrodes (2x) | |
Maximum sample size | 0.315' (8 mm) height, 1.18' (30 mm) diameter | |
Temperature range | 5 K to 600 K | |
Lower electrode | Sliding stage with screw adjustment. Spring-loaded to allow sample expansion / contraction | |
Connections | 4 BNC terminals 2 or 4 terminal measurements | |
Internal connections | High temperature coaxial cables | |
Sample measurement | Uses guard ring techniques to reduce 'fringing' | |
Sample heater | Located close to sample with isothermal shield | |
Temperature sensor | Type E thermocouple | |
Liquid Sample Holder (included) | ||
Position | Locates between the electrodes in the solid sample holder | |
Holder materials | Gold-plated brass electrodes (2x), PEEK body | |
Temperature range | 5 K to 500 K | |
Liquid volume | 0.65 mL | |
Dimensions | 0.315' (8 mm) high, 1.18' (30 mm) diameter | |
System Compatibility | The model 129610A Cryostat is fully compatible with all Solartron Analytical materials test systems. |
650,00 €