T-VER-8044-100 kW Transducers with 4-20 mA o/p View larger

T-VER-8044-100 kW Transducers with 4-20 mA o/p

T-VER-8044-100

Veris

New

Transducer for Power and consumption monitoring

More details

Volume discounts

Quantity Price
You Save
%
1+ 987,00 € 0%
5+ 957,39 € 3%
10+ 927,78 € 6%
15+ 898,30 € 8.9873%

987,00 €

Add to wishlist

Manual PDF Kits to monitor Electricity, Power & Energy
The Veris AC Kilowatt Transducer incorporates three split-core AC currentsensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a FlexSmart Analog Module. Because these sensors tie directly into the line, they should be used only by qualified personnel. NOTE: Not recommended for use with variable frequency drives.
  • Veris T-VER-8044-100 480 VAC, 100 Amp Kilowatt Transducer (Requires transducer S-FS-CVIA).
  • Generates a 4-20 mA output (that represents 0 to 83.14 KW) valid for any Data Logger.
  • CE marking not available

The Veris AC Kilowatt Transducer incorporates three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand).
Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a HOBO Energy Logger Analog Module.

IMPORTANT NOTES: Because these sensors tie directly into the line, they should be used only by qualified personnel.
Not recommended for use with variable frequency drives.

Requires analog port selection during HOBO U30 RX3000 system configuration and use of a S-FS-CVIA when using the H22-001 logger.
When using a U12 logger, this sensor requires a 4-20mA input cable (CABLE-4-20mA) and external power provided by an AC adapter (AC-SENS-1).

• Split-core installation eliminates the need to remove conductors
• Self-contained 0 to 100 AMP current transducer for 1 or 3-phase Power Monitoring
• Precision meter electronics

• Includes 3 100 Amp Split-Core Current Transformers (CT)
• Input primary voltage: 480 Volts AC rms
• Accuracy: ±1% per ANSI (C12.1) (from 10 to 100% of CT rating)
• Number of phases monitored: 3 • Frequency: 50/60 Hz
• Internal isolation: 2000 VAC rms
• Insulation class: 600 VAC rms
• Operating temp range: 0 to 60°C (32° to 140°F)
• Operating humidity range: 0 to 95% RH, non-condensing
• Output signal to FlexSmart: 4-20mA
• Supply powered (current loop): 9-30 VDC, 30mA max
• Current transformer: 100 Amp AC
• Opening dimensions: 3.8cm x 3.2cm (1.5' x 1.25')
• Dimensions of each CT: 10.7cm x 12.1cm x 2.9cm (4.2” x 4.75” x 1.13”)
• Requires FlexSmart Analog Module (S-FS-CVIA)