CO2 air quality sensor with measurement range switch View larger

CO2-A/A CO2 air quality sensor with measurement range switch (with/without display)

Fuehler Systeme

New

The CO2-A / A air quality sensor records the concentration of CO2 in the air around 3 different measuring ranges (0-2000 ppm, 0-5000 ppm, 0-10000 ppm) via an infrared sensor non-dispersive (NDIR) and converts this measured value into a linear 0-10 V or 4-20 mA output signal. Protection type IP65.

290,00 €

tax excl.

Add to wishlist

As an option the air quality sensor has a potential-free changeover contact and a backlit display. The display content can be rotated in 90° steps using a menu and the measured value, the switching threshold set, the state of the relay, the MIN/MAX measured values for the selected intervals (1 h / 6 h / 12 h / 24 h) etc. can be read out.
3 different measuring ranges can be selected (0-2000 ppm, 0-5000 ppm, 0-10000 ppm) which can be switched, according to requirements, by the innovative DIP switching technology.
The zero point balance depending on the actual ambient conditions can be performed on the device by manual calibration. The quality sensor performs an automatic self-calibration at regular interval, thus ensuring a long-term stable CO2 measurement.

Measurement range CO2 0-10000 ppm
Scales 0-2000/5000/10000 ppm
Accuracy 0-2000 ppm: ±50 ppm + 2% f. mv, 0-5000 ppm: ±50 ppm + 3% f. mv, else: ±100 ppm + 5% f. mv (at 20°C, 1013 mbar, auto-calibration ON)
Temperature dependency CO2: 5 ppm / K
Pressure dependency CO2: 1,6% f. mv/kPa
Response time (t90) < 5 min
Long term stability ±1% FS/year
Sensor Non-dispersiver Infrarot Sensor (NDIR)
Sensor protection sinter filter
Running-in time 10 min
Supply voltage 24 V AC/DC (±5%)
Current consumption Ø 100 mA
Analogue output 0-10 V 3-wire connection
Analogue output 4-20 mA 3-wire connection
Alarm output 1 x potential-free change-over contact, 48 V, 1 A
Electrical connection screw terminals max. 1,5 mm²
Housing Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003
Cable gland PG11 high-strength cable gland with strain relief
Display optional LCD display with backlight on/off/auto
Dimensions Housing: L 89 x W 80 x H 47 mm
Protection type IP65
Protection class III
Working range r.H. 0...98% r.H. in contaminant-free, non-condensing air
Working temperature 0...+50°C
Storage temperature -20...+50°C
Initial operation After switch-on of the device follows a self-test and the tempering, which takes ca. 10 minutes depending on the environmental conditions. At this time the analogue output drifts from the actual measurement value.
Automatic calibration To ensure an excellent long-term stability, in the interval of 7 days starts an automatic recalibration. This feature can be disabled on the device by DIP switch.
Manual calibration The manual calibration of the output signal to 400 ppm (zero point) will be started by pushing the button on the circuit board (push ca. 5 s until LED is blinking). Before this it is to ensure a non-stop operating of min. 10 minutes on fresh air. After successful calibration the LED will be deactivated.
Installation screw fastening
Approvals CE, EAC, RoHS

30 other products in the same category: